Assist 4D probe; realize the probe via the ID code; swap the 4D generate signal by means of the electrical relay to help make the 4D probe work Usually. 4.2.two Main board The primary board could possibly be divided into two components: front-conclusion of the most crucial board and back-end of the leading board.
Optimum 4 times tasking for a single transmitted beam, resulting in outstanding time resolution and higher frame price.
Get a whole and extended watch from the anatomical construction by way of panoramic imaging coupled with velocity indicator and forward/backward scan skill earning scanning less difficult, smoother and more controllable.
Untuk memenuhi janji menyediakan perawatan kesehatan berkualitas tinggi dan efektif, Mindray terus mengembangkan kemajuan teknologi medis untuk meningkatkan kualitas perawatan pasien. Dilengkapi dengan PW Doppler dan kemampuan 3D/4D, DP-50Exp menawarkan lebih dari yang Anda harapkan.
Slice off cable ties connecting the most crucial unit over the Display screen by diagonal cutting pliers, and afterwards pull out the corresponding cable plugs.
Mindray’s new era of black & white ultrasound method, DP-fifty Specialist, is provided with Innovative imaging systems making it possible for further penetration and more quickly graphic acquisition with larger resolution.
Web site a hundred forty five Cleanse control panel Applications: dry smooth fabric, gentle soapy water Process: Use dry gentle cloth to scrub the surface area of your technique. In the event the system is dirty, moisten the soft cloth with moderate soapy drinking water and wipe off any stains. Use dry soft cloth to get rid of any dampness and permit all tough surfaces to completely air-dry. Page 146: Clean The Peripherals
Find much better diagnostic information by means of extended watch from the anatomical construction on all convex probes.
Permits use of numerous scanned angles to sort only one graphic, leading to Increased contrast resolution and enhanced visualization
five.2.3 Geometric positioning precision Longitudinal geometric positioning accuracy Examination Move: Do adjustments as just how in testing the maximum depth. File the gap by 20mm Just about every phase within the longitudinal targets line utilizing the measurement caliper; Select the value with the greatest error (to 20mm), compute the precision using the system beneath The measurement caliper ought to be positioned on the higher edge of the concentrate on, Take note:... Page seventy nine Transverse geometric positioning precision Examination Move: Address the scan surface area in the phantom with h2o or few gel, gently Call the probe With all the scan surface area Modify the depth, generating the transverse targets being shown from the picture. Modify the focus point to generally be posited beside the transverse targets (the conventional is not really distinct) Adjust parameters like attain, TGC, building Just about every transverse targets to get clearly exhibited. Web site 80 5.five.two.4 Blackout Space Exam Stage: Protect the scan surface of your phantom with water or pair gel, gently Make contact with the probe Along with the scan area Regulate the depth at a lessen value, and established the main target at the nearest location to the scan area. Lower the worth of parameters like AP, Gain till the qualifications sounds just may be Dp50rb witnessed. Page 81: Software package Enhance And Maintenance
Kebutuhan Anda akan alat profesional dan canggih yang dikombinasikan dengan pencitraan berkualitas dan kemudahan kegunaan kini dapat dipenuhi dengan sistem portabel baru Mindray DP-50Exp.
Observe: Ahead of uploading the log, make certain the ultrasound process continues to be connected to network, in any other case, the technique may perhaps alert “couldn't connect with server” The server (smtp.
NOTE: Right before inserting the connector to the probe port, inspect the connector pin. If the pin is bent, will not use the probe right up until it's been inspected / repaired / changed. Installing Peripherals For the models of your supported peripherals, please check with “2.
Right after changing the CPU module, key file has to be produced Yet again based on the new MAC tackle and penned into HDD of the machine. Or else, the configuration purpose of your product will likely be dropped. Soon after taking away the CPU module, Clear away panhead screws with washers (twelve M3X6) mounted on the principle unit box, you may take off the board. Web page 118 Determine 8-29 Disassemble the Control Panel Assembly (one) Maintain the upper fringe of user interface assembly, and open up the user interface. Figure 8-thirty Disassemble the Control Panel Assembly (two) Immediately after taking away one particular countersunk head self-tapping screw PT3X10 set on the control panel and just take out the plug from the keyboard and the primary device connecting cables, you might get rid of the user interface assembly.
A sensible new shape, enhanced mobility and hassle-free operation make DP-50 compatible for all medical options.